Skip to main content

TS 324 Panel

PBR Panel
PBR Panel

Panel Features

  • Coverage Width
    24″
  • Rib Spacing
    24″
  • Rib Height
    3-1/16″
  • Min Slope
    1/2″ : 12″
  • Panel Attachment
    Standing Seam
  • Gauge
    24 & 22

Panel Specifications

PANEL TOLERANCES
PANEL GAUGE DESIGN THICKNESS
MINIMUM DELIVERED THICKNESS
24 0.0221 0.0221
22 0.0275 0.0275
Section Properties
NEGATIVE BENDING POSITIVE BENDING
PANEL GAUGE Fy
(KSI)
WEIGHT
(PSF)
Ixx
(IN.4/FT.)
Sxx
(IN.3/FT.)
Ma
(KIP-IN./FT.)
Ixx
(IN.4/FT.)
Sxx
(IN.3/FT.)
Ma
(KIP-IN./FT.)
24 50 1.133 0.3620 0.1517 4.541 0.1520 0.0924 2.766
22 50 1.406 0.4475 0.1875 5.626 0.1965 0.1235 3.698
*Fy is 80-ksi material reduced to 60-ksi in accordance with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members – A2.3.2.

Notes:

  • All calculations for the properties of TS 324 panels are calculated with the 2007 edition of the North American Specification for the Design of Cold-Formed Steel Structural Members.
  • All values are for one foot of panel width.
  • Ixe is for deflection determination.
  • Sxe is for bending.
  • Maxo is allowable bending Moment.
  • Positive Bending refers to compression above the x-axis, i.e. top of panel in compression.
  • Negative Bending refers to compression below the x-axis, i.e. bottom of panel in compression.
  • Panel weight is based on panel coverage width.
  • Panel gauge refers to the design and minimum delivered uncoated thicknesses noted in table below.
The Engineering data contained herein is for the express use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

A Positive Move!

We give APEC a big thumbs up! Storage Development Inc. has been building storage projects for over 20 years and we have learned that there will always be problems to solve. Teaming up with Rapid Building Solutions and a metal supplier like APEC has been a positive move for us.

Brad Brodie
SDi – Storage Developers

Request a quote or talk with a rep. Contact us today.